The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.
- Four Ring Probe
- Quick Connect
- Ergonomic, One-Handed Operation
Features/Benefits:
Compact, rugged, waterproof (IP67) design
Methods
- USP <645> capable for checking the quality of water used in pharmaceutical manufacturing
Salinity readings
- Seawater salinity can be displayed as % NaCl, natural seawater scale (ppt) or practical salinity scale (PSU)
Auto-ranging and fixed range options
Calibration
- Perform up to a five point calibration for enhanced accuracy
GLP Features
- GLP data provides calibration data including date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS)
Calibration timeout to alert the user at a defined interval when the calibration has expired
Auto Hold
- Freezes first stable reading on the display
Multiple language selection
PRIMARY APPLICATIONS: Environmental, pharmaceutical, plating, water treatment, food manufacturing, and water and wastewater
| Specification | Detail |
|---|---|
| sku | HI98192 |
| Temperature Range | -20.0 to 120.0 °C (-4.0 to 248.0 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Temperature Accuracy @ 25°C / 77°F | ±0.2 °C (±0.4 °F) (excluding probe error) |
| Temperature Calibration | one or two points |
| EC Range | 0 to 400 mS/cm (shows values up to 1000 mS/cm) Actual conductivity 1000 mS/cm 0.001 to 9.999 µS/cm* 10.00 to 99.99 µS/cm 100.0 to 999.9 µS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (autoranging) |
| EC Resolution | 0.001 µS/cm* / 0.01 µS/cm / 0.1 µS/cm 0.001 mS/cm / 0.01 mS/cm / 0.1 mS/cm |
| EC Accuracy @25°C/77°F | ±1% of reading (±0.01 µS/cm or 1 digit whichever greater) |
| EC Calibration | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
| TDS Range | 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 g/L 10.00 to 99.99 g/L 100.0 to 400.0 g/L (autoranging) |
| TDS Resolution | 0.01 ppm / 0.1 ppm / 0.001 g/L / 0.01 g/L / 0.1 g/L |
| TDS Accuracy @ 25°C / 77°F | ±1% of reading (±0.05 ppm or 1 digit whichever greater) |
| TDS Conversion Factor | 0.40 to 1.00 |
| Resistivity Range | 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm* (autoranging) |
| Resistivity Resolution | 0.1 Ω•cm / 1 Ω•cm / 0.01 KΩ•cm / 0.1 KΩ•cm / 1 KΩ•cm 0.01 MΩ•cm / 0.1 MΩ•cm* |
| Resistivity Accuracy (@25°C/77°F) | ±1% of reading (±10 Ω•cm or 1 digit whichever greater) |
| Salinity Range | % NaCl: 0.0 to 400.0 % Seawater scale: 0.00 to 80.00 (ppt) Practical salinity: 0.01 to 42.00 (PSU) |
| Salinity Resolution | 0.1 % / 0.01 ppt / 0.01 PSU |
| Salinity Accuracy (@25°C/77°F) | ±1% of reading |
| Salinity Calibration | max. one point only in % range (with HI7037 standard) use conductivity calibration for all other ranges |
| Temperature Compensation | NoTC, Linear, Non Linear ISO/DIS 7888 std |
| Log Feature | on-demand: 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) |
| Connectivity | PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable |
| Power Supply | 1.5V AA batteries (4) |
| Power Consumption | approximately 100 hours of continuous use (without backlight), 25 hours with backlight |
| Environment | 0 to 50 °C (32 to 122 °F) max. RH 100% IP67 |
| Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in. |
| Weight | 400 g (14.2 oz) |
| Ordering Information | HI98192 is supplied with HI763133 stainless steel conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. |
| Warranty | 2 years |
| Recommended Probe | HI763133 four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9′) cable (included) |